A review of a proposed nine-storey hotel with a basement in Accra revealed serious problems across the architectural, structural, geotechnical, mechanical and electrical designs. Structural elements were inadequately designed, and the proposed foundation did not address weak, collapsible soils and high groundwater. The confined site, bordered by existing buildings, also made basement excavation hazardous: slope-stability analysis found a factor of safety as low as 0.391, far below acceptable levels.<br /><br />The original proposal for a basement raft was abandoned. A shallow raft without a basement was also considered impractical because it would require extensive ground improvement. Micropiles were judged uneconomical, so the team selected a piled raft supported by bored concrete piles.<br /><br />Further investigation uncovered major discrepancies in the original geotechnical report. While it indicated increasingly dense ground below about 8 m, confirmatory boreholes found medium-dense silty sand at that depth. A third witnessed borehole confirmed the revised findings, prompting the team to redesign the piles to reach stronger ground. The final design used 103 bored piles, each 600 mm in diameter and 17.5 m long, with a 1 m-deep pile cap. Axial and lateral pile behaviour was analysed and incorporated into a structure–pile–soil interaction model.<br /><br />The case highlights the need to verify third-party geotechnical data when results are doubtful, thoroughly review all design disciplines, and maintain open discussions among project stakeholders—particularly when safety and costs are affected. The authors warn that inaccurate or unethical engineering practice can lead to unsafe foundations and excessive settlement.
Keywords
hotel design
geotechnical investigation
piled raft foundation
bored concrete piles
weak soils
groundwater
basement excavation
slope stability
structural design review
foundation safety
×
Please select your language
1
English