A COMPARATIVE STUDY ON BEHAVIOR OF BUCKET PILE IN SAND ACCORDING TO INSTALLATION METHODS
Availability
On-Demand
Cost
$0.00
Credit Offered
No Credit Offered

Model tests have been performed to investigate the vertical, horizontal and cone tip resistances of bucket pile embedded in sand by different installation methods; suction force by pump and jacking force by actuator. Micro-cone penetrometer is used to eva

Subjects: bucket pile, jacking installation, suction installation, pull-out test, micro-cone penetrometer

Author: Juhyung Lee, Jinung Do, Sung-Ryul Kim

Publisher: DFI

Annual Conference Proceedings, International Conference Proceedings