Super Cells are an innovative, open-shaped bi-directional static load testing device used to promote concrete flow during placement while utilizing greater cross-sectional area of the pile to achieve large applied axial loads at relatively low hydraulic pressures (≤ 250 bar). This paper describes the results of multi-level load testing performed on a sacrificial drilled shaft that was 3.8 m (12.7 ft) in diameter and 110.6 m (363 ft) in length for the Jiaxing-Shaoxing River Crossing Bridge that spans Hangzhou Bay in Shaoxing, China. The test shaft was instrumented with embedded strain gauges and telltale rods along with displacement transducers at the top of the pile to measure the load-induced displacements along the length of the shaft. Load testing was performed twice using a Super Cell placed near the tip of the shaft, prior and subsequent to tip post-grouting, and then again using a Super Cell placed higher in the shaft. The axial resistance for the tested conventional drilled shaft was more than 5 times greater than the estimated axial resistance. In addition, the axial resistance after tip post-grouting (347, 100 kN (39, 033 ton)) was about 5.3% greater than the ungrouted axial resistance (329, 600 kN (37, 050 ton)).
Subjects: drilled shaft, Super Cells, bi-directional static load testing, tip post-grouting
Author: Antonio Marinucci, PhD, MBA, P.E., Robin Mao and Diane Reid