Case Histories of Circular Secant Pile Access Shafts for Tunnels
Availability
On-Demand
Cost
$0.00
Credit Offered
No Credit Offered

Circular secant pile shafts were installed along the tunnel alignments for both the Ohio Canal Interceptor Tunnel project in Akron, Ohio and the Ohio River Tunnel project in Louisville, Kentucky. The diameters ranged from 34 to 51 feet and the depths ranged from 49 to 107 feet. Verticality and concrete volumes were measured on all piles to verify compliance with the design, which for some shafts consisted of a finite element model with multiple openings using unreinforced concrete secant piles. All secant piles were drilled into rock to seal off the groundwater. This paper will discuss the design, construction and quality control of the secant piles for these projects.

Subjects: None provided

Author: Stanley L. Worst, Matthew J. Niermann and Piotr Kozlowski

Annual Conference Proceedings
Powered By