Conventionally, cement deep mixing (CDM) columns are designed to have constant diameters over the improved depth as this facilitates the construction procedures. However, this design pattern may be inefficient in cases of spread footings or shallow foundations. This paper first briefly introduces principles of an improved CDM method that can create head-enlarged CDM (termed PF) columns. A simple analysis approach was introduced to obtain optimal shape of PF columns that results in minimum settlement. The effectiveness of this improved method over the conventional CDM method was then illustrated by settlement analysis for an actual footing in a case study using two recommended analytical methods in the literature. Analysis results from the case indicated that by using the same amount of soil-cement mixed volumes, settlement from a footing on PF columns can reduce up to 10 % compared with that from the same footing on CDM columns. In addition, a material quantity comparison for the case indicated that to have the same settlement values the volume of each PF column can be reduced of around 10% compared with that of the CDM column.

Subjects: CDM method, head-enlarged CDM columns, PF method, settlement