Abstract:
This is a case study on ground improvement using Stone columns at Kokrajhar in Assam which comes under seismic Zone V as per IS: 1893. The strata at site comprised of mostly fine sands with low SPT- N values, fine content less than 10% and ground water table (GWT) at shallow depth. As ground water table subjected to seasonal variation, water table is considered at ground level for designing purpose. The geotechnical profile of the boreholes was analysed on the guidelines of IS 1893 (Part 1) -2016 and it was observed that the liquefaction potential of the soil layers is prominent and ground improvement is inevitable up to a depth of 9.5 m below existing ground level. In order to mitigate the liquefaction of soil layer, Stone columns were proposed. The in-situ soil is densified using wet top feed vibro- replacement method with an area replacement ratio of 16%, so that the relative density of the soil can be enhanced to prevent liquefaction risk. Correlation between relative density, fines content and increment of SPT N –value given by Tokimatsu and Yoshimi (1983) was used for designing purpose. Field tests such as SPTs were carried out at site to validate the extent of SPT (N) improvement. Detail comparison of pre and post density, SPT N values and CRR values were discussed in this paper.