Jet Grout Underpinning to Support the Waterman Hospital
Availability
On-Demand
Cost
$0.00
Credit Offered
No Credit Offered

The Waterman Hospital in Tavares, Florida was undergoing an expansion and required a below-grade excavation immediately adjacent to the Emergency Department. This wing of the hospital was under high traffic and required uninterrupted access for ambulances as well as helicopter landings. The below-grade expansion was also next to a part of the hospital which did not have a basement. Tiedback soldier beams and wood lagging were used as the earth retention system where the shoring line was not immediately adjacent to the existing structure. Structural jet grout underpinning was used to support the existing building and to serve as the earth retention system in the more sensitive area. Jet grout underpinning was chosen to minimize movements, loss of ground and settlement of the structure which was bearing on clean sand deposits. This paper will discuss the design, quality control and construction of jet grouting and its application to this project.

Subjects: jet grouting, underpinning, earth retention system

Author: Stanley L. Worst, Piotr Kozlowski and Matthew J. Niermann

Annual Conference Proceedings