This paper presents the performance of nineteen open-ended steel pipe piles driven through highly variable overburden soils into glacial till and schist bedrock. The piles were 16 inches in diameter and 0.656 inches thick, with yield strength of 50 ksi. The piles were designed for a service capacity of 250 kips and were driven to achieve an ultimate geotechnical capacity of at least 500 kips. Due to the large variation in the ground conditions, installed pile lengths ranged from 25 to 66 feet. Some piles were driven to refusal on the bedrock while others were terminated at final driving resistance of 2 to 7 blows/in. Two piles were suspected to be plugged during driving while others did not. Each pile was instrumented with strain gages and accelerometers near the pile top, and observed using a Pile Driving Analyzer (PDA) to provide preliminary guidance on pile capacity achieved at end of initial drive (EOID). The influence of plugged and unplugged pile toe conditions on the interpretation of pile capacity was investigated using Case Pile Wave Analysis Program (CAPWAP). Characteristics of driving energy, compressive and tensile stresses developed in the steel pipe piles, and the resulting pile deformation behavior are discussed.
Subjects: steel pipe pile, drivability, dynamic pile testing, CAPWAP analysis, soil plug
Author: Chu E. Ho and Paul Napoli