Nondestructive testing of drilled shaft foundations via Crosshole Sonic Logging (CSL) is often performed as part of the quality assurance process to assess the soundness of concrete. The intent of CSL testing is to identify irregularities such as soil intrusion, necking, soft bottom, segregation, voids and other defects that could result in poor structural performance of the foundation. Over time, CSL rating criteria based on first arrival time and relative energy have incorrectly evolved to often be the sole means of determining the acceptability of a shaft. Some of these criteria have found their way into regulatory agency specifications, with acceptance values often differing from agency to agency.
The purpose of this document is to review the state of the practice (including experience gained over the past 20 years), propose improved CSL rating criteria and make recommendations for additional assessment, as well as educate the industry on the proper interpretation of CSL test. CSL test results alone should not be the sole means of rejecting or accepting a shaft.
Edited by: CSL Task Force of DFI Codes and Standards, Drilled Shafts and Testing and Evaluation Committee Members
Sponsored by: DFI